Sessão de Encontro com o Autor – Tema Livre (Pôster)


Código

P51

Área Técnica

Glaucoma

Instituição onde foi realizado o trabalho

  • Principal: Universidade de São Paulo (USP)

Autores

  • VALERIA BATISTA BORECK SEKI (Interesse Comercial: NÃO)
  • Vitor Joaquim Barreto Fontes (Interesse Comercial: NÃO)
  • Marcelo Jordão L da Silva (Interesse Comercial: NÃO)
  • George Cunha Cardoso (Interesse Comercial: NÃO)
  • Zane Zenon Zemborain (Interesse Comercial: NÃO)
  • Carlos Gustavo de Moraes (Interesse Comercial: NÃO)
  • Jayter Silva de Paula (Interesse Comercial: NÃO)

Título

Minimum Rim Width and Retinal Nerve Fiber Layer Thickness in Coincident Clinical and Automated Optic Disc Boundaries.

Objetivo

To evaluate the relationship between correspondent Minimum Rim Width (MRW) and circumpapillary Retinal Nerve Fiber Layer (cpRNFL) thicknesses in eyes with coincident clinical and Bruch's membrane opening (BMO) demarcation of the Optic Nerve Head (ONH) boundaries, determined by the spectral-domain Optical Coherence Tomography (sdOCT).

Método

Twenty-two eyes of 11 healthy subjects (53.2 ± 19.6 years old; spherical equivalent: -0.3 ± 2.9 D) underwent sdOCT examination (Spectralis, Heidelberg Engineering, Germany). The study included all 48 sdOCT pairs of scans (MRW, and 3.5 mm cpRNFL values) from eyes with coincident BMO and clinical ONH boundaries' demarcation. The normalized differences between the paired values were plotted as a standard 360-degree polar curve.

Resultado

Eyes with coincident ONH boundaries delimitation showed lower normalized difference in the temporal Garway-Heath sector. A standard 360-degrees polar curve centered at the ONH was constructed and presented low dispersion values (95% IC: 5.1 to 7.24 um; Figure 1).

Conclusão

The standard 360-degree curve of the relationship between MRW and cpRNFL in eyes with coincident BMO- and clinical-based ONH delimitation presents a robust mean value and clinically acceptable variance. This information may be used as a reliable tool for future studies involving the investigation of eyes with discrepant BMO- and clinical-based ONH boundaries.

Promotor

Realização - CBO

Organização

Organizadora

Transporte Terrestre

Transporte Terrestre

Agência de Turismo

Agência Oficial de Turismo

Agência Web

Sistema de Gerenciamento desenvolvido por Inteligência Web

Patrocinador Platina

Genom
Johnson & Johnson

Patrocinador Ouro

Allergan

Patrocinador Prata

Alcon
Latinofarma

Patrocinador Bronze

Essilor
Ofta
Zeiss

Patrocínio

Roche

66º Congresso Brasileiro de Oftalmologia

07 a 10 de setembro de 2022 | Curitiba/PR

Política de privacidade